I. Raad, H. Hanna, and D. Maki, Intravascular catheter-related infections: advances in diagnosis, prevention, and management, Lancet Infect. Dis, vol.7, pp.645-657, 2007.

C. Beloin, N. Fernández-hidalgo, and D. Lebeaux, Understanding biofilm formation in intravascular device-related infections, Intensive Care Med, vol.43, pp.443-446, 2017.
URL : https://hal.archives-ouvertes.fr/pasteur-01377078

P. B. Bookstaver, K. E. Rokas, and L. B. Norris, Stability and compatibility of antimicrobial lock solutions, Am. J. Health-Syst. Pharm. AJHP Off. J. Am. Soc. Health-Syst. Pharm, vol.70, pp.2185-2198, 2013.

S. Hogan, M. Zapotoczna, and N. T. Stevens, In vitro approach for identification of the most effective agents for antimicrobial lock therapy in the treatment of intravascular catheter-related infections caused by Staphylococcus aureus, Antimicrob. Agents Chemother, vol.60, pp.2923-2931, 2016.

L. A. Mermel, M. Allon, and E. Bouza, Clinical practice guidelines for the diagnosis and management of intravascular catheter-related infection, 2009.

, Update by the Infectious Diseases Society of America, Clin. Infect. Dis. Off. Publ. Infect. Dis. Soc. Am, vol.49, pp.1-45, 2009.

J. A. Justo and P. B. Bookstaver, Antibiotic lock therapy: review of technique and logistical challenges, Infect. Drug Resist, vol.7, pp.343-363, 2014.

D. Lebeaux, J. Ghigo, and C. Beloin, Biofilm-related infections: bridging the gap between clinical management and fundamental aspects of recalcitrance toward antibiotics, Microbiol, Mol. Biol. Rev. MMBR, vol.78, pp.510-543, 2014.

M. G. Betjes and M. Van-agteren, Prevention of dialysis catheter-related sepsis with a citrate-taurolidine-containing lock solution, Nephrol. Dial. Transplant, vol.19, pp.1546-1551, 2004.

P. B. Bookstaver, J. C. Williamson, and B. K. Tucker, Activity of novel antibiotic lock solutions in a model against isolates of catheter-related bloodstream infections, Ann. Pharmacother, vol.43, pp.210-219, 2009.

I. I. Raad, R. Y. Hachem, and H. A. Hanna, Role of ethylene diamine tetra-acetic acid (EDTA) in catheter lock solutions: EDTA enhances the antifungal activity of amphotericin B lipid complex against Candida embedded in biofilm, Int. J. Antimicrob. Agents, vol.32, pp.515-518, 2008.

M. C. Weijmer, M. A. Van-den-dorpel, and P. J. Van-de-ven, Randomized, clinical trial comparison of trisodium citrate 30% and heparin as catheterlocking solution in hemodialysis patients, J. Am. Soc. Nephrol, vol.16, pp.2769-2777, 2005.

Z. Liu, Y. Lin, and Q. Lu, In vitro and in vivo activity of EDTA and antibacterial agents against the biofilm of mucoid Pseudomonas aeruginosa, Infection, vol.45, pp.23-31, 2017.

A. Chauhan, D. Lebeaux, and J. Ghigo, Full and broad-spectrum in vivo eradication of catheter-associated biofilms using gentamicin-EDTA antibiotic lock therapy, Antimicrob. Agents Chemother, vol.56, pp.6310-6318, 2012.
URL : https://hal.archives-ouvertes.fr/pasteur-01126606

G. Council-of-europe and . Sulfate, European Directorate for the Quality of Medicines & HealthCare, vol.88, pp.2525-2526, 2016.

J. A. Ji, E. Ingham, and J. Y. Wang, Effect of EDTA and methionine on preventing loss of viscosity of cellulose-based topical gel, AAPS PharmSciTech, vol.10, pp.678-683, 2009.

A. Rudin, A. Healey, and C. A. Phillips, Antibacterial activity of gentamicin sulfate in tissue culture, Appl. Microbiol, vol.20, pp.989-990, 1970.

N. D. Mullins, B. J. Deadman, and H. A. Moynihan, The impact of storage conditions upon gentamicin coated antimicrobial implants, J. Pharm. Anal, vol.6, pp.374-381, 2016.

G. G. Christianson and T. A. Koski, A comparison of a disposable membrane filtration system with a direct inoculation system for the sterility testing of veterinary biologics, J. Biol. Stand, vol.11, pp.83-89, 1983.

A. I. Al-amoud, B. J. Clark, and H. Chrystyn, Determination of gentamicin in urine samples after inhalation by reversed-phase high-performance liquid chromatography using pre-column derivatisation with o-phthalaldehyde, J. Chromatogr. B, vol.25, pp.89-95, 2002.

M. C. Chuong, J. Chin, and J. W. Han, High performance liquid chromatography of gentamicin sulfate reference standards and injection USP, Int. J. Pharm. Anal, vol.4, p.25, 2013.

P. J. Kuehl, S. De, B. Eppler, and J. Marsters, Development and validation of an HPLC assay for dual detection of gentamicin sulfate and leucine from a novel dry powder for inhalation, J. Anal. Bioanal. Tech, vol.3, pp.1-4, 2012.

K. Ruckmani, S. Z. Shaikh, and P. Khalil, A simple and rapid high-performance liquid chromatographic method for determining tobramycin in pharmaceutical formulations by direct UV detection, Pharm. Methods, vol.2, pp.117-123, 2011.

A. S. Kord, I. Tumanova, and W. L. Matier, A novel HPLC method for determination of EDTA in a cataract inhibiting ophthalmic drug, J. Pharm. Biomed. Anal, vol.13, pp.575-580, 1995.

E. Caudron, S. Baghriche, and P. Prognon, Simultaneous quantification of gentamicin and colistin sulfate in pharmaceuticals using ion-pairing and polarity gradient chromatography with low-UV detection, Chromatographia, vol.76, pp.747-755, 2013.

K. Stypulkowska, A. Blazewicz, and Z. Fijalek, Determination of gentamicin sulphate composition and related substances in pharmaceutical preparations by LC with charged aerosol detection, Chromatographia, vol.72, pp.1225-1229, 2010.

S. K. Branch, Guidelines from the International Conference on Harmonisation (ICH), vol.38, pp.798-805, 2005.

G. A. Shabir, Validation of high-performance liquid chromatography methods for pharmaceutical analysis: Understanding the differences and similarities between validation requirements of the US Food and Drug Administration, the US Pharmacopeia and the International Conference on Harmonization, J. Chromatogr. A, vol.987, pp.57-66, 2003.

M. Blessy, R. D. Patel, and P. N. Prajapati, Development of forced degradation and stability indicating studies of drugs-a review, J. Pharm. Anal, vol.4, pp.159-165, 2014.

L. D. Sabath, J. I. Casey, and P. A. Ruch, Rapid microassay of gentamicin, kanamycin, neomycin, streptomycin, and vancomycin in serum or plasma, J. Lab. Clin. Med, vol.78, pp.457-463, 1971.

J. M. Andrews and R. Wise, A comparison of the homogeneous enzyme immunoassay and polarization fluoroimmunoassay of gentamicin, J. Antimicrob. Chemother, vol.14, pp.509-520, 1984.

S. A. Brown, D. R. Newkirk, and R. P. Hunter, Extraction methods for quantitation of gentamicin residues from tissues using fluorescence polarization immunoassay, J. Assoc. Off. Anal. Chem, vol.73, pp.479-483, 1990.

V. Manyanga, O. Grishina, and Z. Yun, Comparison of liquid chromatographic methods with direct detection for the analysis of gentamicin, J. Pharm. Biomed. Anal, vol.45, pp.257-262, 2007.

V. Manyanga, K. Kreft, and B. Divjak, Improved liquid chromatographic method with pulsed electrochemical detection for the analysis of gentamicin, J. Chromatogr. A, vol.1189, pp.347-354, 2008.

I. Clarot, P. Chaimbault, and F. Hasdenteufel, Determination of gentamicin sulfate and related compounds by high-performance liquid chromatography with evaporative light scattering detection, J. Chromatogr. A, vol.1031, pp.281-287, 2004.

N. C. Megoulas and M. A. Koupparis, Development and validation of a novel LC/ ELSD method for the quantitation of gentamicin sulfate components in pharmaceuticals, J. Pharm. Biomed. Anal, vol.36, pp.73-79, 2004.

A. Joseph and A. Rustum, Development and validation of a RP-HPLC method for the determination of gentamicin sulfate and its related substances in a pharmaceutical cream using a short pentafluorophenyl column and a charged aerosol detector, J. Pharm. Biomed. Anal, vol.51, pp.521-531, 2010.

H. Curiel, W. Vanderaerden, and H. Velez, Analysis of underivatized gentamicin by capillary electrophoresis with UV detection, J. Pharm. Biomed. Anal, vol.44, pp.49-56, 2007.

K. Vu?i?evi?-pr?eti?, R. Cservenák, and N. Radulovi?, Development and validation of liquid chromatography tandem mass spectrometry methods for the determination of gentamicin, lincomycin, and spectinomycin in the presence of their impurities in pharmaceutical formulations, J. Pharm. Biomed. Anal, vol.56, pp.736-742, 2011.

J. F. Chissell, M. Freeman, and J. S. Loran, British pharmacopoeial gentamicin sulphate component ratio test by high-performance liquid chromatography. The effect of derivative breakdown on final result, J. Chromatogr, vol.369, pp.213-217, 1986.

J. H. Albracht and M. S. De-wit, Analysis of gentamicin in raw material and in pharmaceutical preparations by high-performance liquid chromatography, J. Chromatogr, vol.389, pp.306-311, 1987.

G. Wang and F. P. Tomasella, Ion-pairing HPLC methods to determine EDTA and DTPA in small molecule and biological pharmaceutical formulations, J. Pharm. Anal, vol.6, pp.150-156, 2016.